Batch BBT-01

Passed QC

Standard-strength concrete

Sample data

Sampled

Casting concrete test cubesSample lab image

Image uploaded: 24 Sept 2026, 05:59 (Bangkok time)

Slump
10cm
Target 10 ± 2 cm
7 days
355ksc
Cube
28 days
440ksc
Cube
View details Batch BBT-01

Materials in this batch

Results

Other results

2 records

Batch BBT-02

Pending

Concrete 240 (sample)

Sampled

  • Slump9.5cm
  • 7 days205ksc
  • 28 daysno value yetAwaiting result
Sample data

Batch BBT-03

Under review

Concrete 320 · cylinder specimens

Sampled

  • Slump12cm
  • 7 days248ksc
  • 28 days336ksc
Sample data